Medium High Voltage Digital Soft Starters
Indusquip Marketing offers a complete range of Soft Starters and will advise and assist in the correct selection
of product for your needs.
Our product will ensure a reliable, quality and affordable solution to all your starting problems.
Ordering Information
Example:
HPMV-SS |
2.3
xxx |
200
x |
230
x |
1+3
x+x |
Enterprise Code |
Main Voltage |
Starter FLC |
Control Voltage |
Options |
Medium Voltage Code |
(1) |
(2) |
(3) |
(4) |
Control Sort |
|
|
|
|
| (1) |
| |
Specify |
For |
|
2.3KV |
2.3KV+10%-15% |
|
3.3KV |
3.3KV+10%-15% |
Main Voltage |
4.16KV |
4.16KV+10%-15% |
|
6.0KV |
6.0KV+10%-15% |
|
6.6KV |
6.6KV+10%-15% |
|
10KV |
10KV+10%-15% |
|
13.8KV |
13.8KV+10%-15% |
|
(2) Starter FLC: 60A, 110A, 200A, 320A, 400A, 600A, 800A
| (3) |
| |
Code Name |
For |
Control Supply Voltage |
110VAC |
100 – 120VAC |
(terminals 1-3) |
220VAC |
200 – 240VAC |
|
110VDC |
100 – 120VDC |
|
220VDC |
200 – 240VDC |
|
| (4) |
| |
Code Name |
Introduction |
Required Options |
1 |
Communications RS-485 MODBUS |
for more than one |
2 |
Communications RS-485 PROFIBUS |
option indicate, for |
3 |
Analogue out function |
example: 1+3 |
4 |
With motor protection of differential |
(Comm. + Analogue) |
5 |
With controller for drive more than one motor |
|
Advantages at a glance
- Eliminates high inrush current and high mechanical torque on start-up
- Soft, stepless acceleration & deceleration
- Unique starting & stopping characteristics
- User friendly, straight forward set-up and operation
- Sophisticated motor protection package
- Heavy duty design: 50°C ambient temperature
- Innovative low voltage test mode – full function testing with a small LV motor, using LV mains
- Advanced Electronic Potential Transformer utilizing Patent Pending “wireless” fiber-optic controlled wiring system
- Each starter is tested for Potential Discharge (corona) to ensure long term reliability
- Power Factor capacitors can be connected directly to the upstream contactor
- IP30 standard, higher protection by special order
- Two optional methods of delivery: Chassis type for self assembly or complete system
- RS485 Communication with MODBUS, PROFIBUS or MODBUS/TCP protocols (others available on request)
- Wide 45-65Hz auto tracking frequency range realized by special software with unique hardware arrangement (designed for Marine, Offshore and Generators operating under continuous frequency fluctuation)
- Torque and current starting and stopping characteristics
- Pump control software
Starting & Stopping
- Soft start & soft stop
- Current limit
- Pump Control characteristics
- Torque and Current control ramps
- Slow speed with electronic reversing
- Pulse start
- Tacho/encoder feedback (option)
- Dual Adjust – 2 start/stop characteristics for varying loads, two-speed motors, etc.
Motor & Starter Protection
- Too many starts & start inhibit time
- Long start time (stall protection)
- Electronic overload with selectable curves
- Electronic shear-pin
- Undercurrent
- Unbalanced current
- Ground fault current
- Phase loss
- Phase sequence and under/over frequency
- Under voltage
- Over voltage
- External faults (2 separate inputs)
- Shorted SCR & wrong connection
- Starter over temperature
- Power on without start signal
- Open by-pass contactor
Set-up & Supervision
- Illuminated LCD with 2 lines, 16 characters each
- Selectable languages: English, German, French or Spanish
- The LCD displays motor current, faults description as well as statistical data
- Easy set-up using six soft-touch keys to change pre-programmed default parameters
- Eight LED’s for a quick display:
- Control voltage On & Self Test OK
- Motor soft starting
- Motor running
- Motor soft stopping
- Motor stopped
- Test Mode Activated
- Dual Adjust mode
- Fault


Use Electric VSD rated motors or force-cooling units for maximum efficiency |